Standards and codes have been developed to ensure that all constructed objects such as buildings and furniture, conform to a minimum level of safety. The codes are designed to protect public health, safety, and general welfare as they relate to the construction and occupancy of buildings and structures. The building code requires all building work comply with the code. Many of the specific standards and codes within Australia are controlled by the Australian Building Codes Board (ABCB), and the details and copies of the standards are available at the ABCB website. BCA building classes The BCA classifies buildings by their use. A building may be made up of a number of classes if it has a mixed use. The BCA identifies the following building classes: Class 1a - a single dwelling or attached dwellings (eg a terrace, duplex, etc) where each dwelling is separated by a fire wall. Class 1b - one or more buildings that constitute a boarding house, guest house, hostel of small scale (ie not exceeding 12 persons or 300m2 in floor area). Class 2 - a building containing two or more dwelling units (eg flats, apartments). Class 3 - a residential building for a number of persons such as a large scale boarding house, guest house, hostel, the residential part of a hotel, motel, school, etc. Class 4 - a dwelling unit that is a part of a commercial use (eg a caretakers/managers flat). Class 5 - an office building. Class 6 - a shop or other building where goods or services are retailed directly to the public. Class 7a - a car park building. Class 7b - a storage building or building where goods are wholesaled (eg a warehouse). Class 8 - a laboratory or a building where a process takes place (eg factory, workshop, etc). Class 9a - a health care building (eg a hospital, clinic, etc). Class 9b - an assembly building (eg community hall, sports hall, etc) Class 9c - an aged care building. Class 10a - a non-habitable building being a private garage, shed or the like. Class 10b - a structure (eg a fence, wall, mast, swimming pool, etc). Building classes and the format of the BCA Volume One Volume One is split into nine sections with the first section containing administrative provisions, the remainder containing technical provisions. Volume One of the BCA is structured so that each technical section contains:
Section A: General Provisions - contains information such as definitions, how buildings are to be classified and the list of guidance documents such as Australian Standards that have been referenced by the BCA as Deemed to Satisfy solutions. Section B: Structure - requirements for the structural stability of the building including the structural resistance that materials and forms of construction must achieve against effects such as dampness, termites, water penetration, etc. Section C: Fire Resistance - requirements for the fire resistance of the building. This is to ensure that not only fire spread from one building to another is prevented but also a building maintains structural stability during a fire to allow for occupants to evacuate and the fire brigade to fight the fire. This is achieved by separation distances between buildings, fire protection to external walls (including any openings such as windows) and the splitting up of the internal spaces of the building into separated compartments. It is important to understand the following terminology in relation to this section:
Section D: Access & Egress - provisions relating to the number, size, type and separation of emergency exits, as well as the distance to an emergency exit. These provisions are determined by the building's class, size of the building and the number of persons the building accommodates. The section also includes provisions relating to the accessibility of a building for people with disabilities. Section E: Services & Equipment - this section identifies the fire safety equipment that must be installed in a building. This equipment includes fire fighting equipment (eg fire hydrants, hose reels, portable fire extinguishers, etc), smoke hazard management (eg smoke detectors and alarms) and emergency lighting and signs. The section also provides the requirements for lift installations when one is installed in a building. As a general rule all buildings require portable fire extinguishers to be installed. The provision of any other equipment is dependant on the size of the building. Section F: Health & Amenity - the requirements for damp & weatherproofing, sanitary facilities, room sizes, light and ventilation and sound insulation. The number of sanitary facilities is dependant on the number of people the building accommodates. Provisions relating to sanitary facilities for people with disabilities are also included in this section. The light and ventilation provision relates to both natural as well as artificial lighting and ventilation. Not all buildings are required to be provided with natural ventilation or lighting. Section G: Ancillary Provisions - this section contains requirements that affect structures that are ancillary to the main use of the building including minor structures (swimming pools, vaults, cool rooms), heating appliances (fireplaces, flues and chimneys) and atrium construction. It also contains requirements for buildings constructed in alpine areas and bush fire prone areas. Section H: Special Use Buildings - the requirements specific to certain buildings such as theatres and public halls. Section I: Maintenance - the requirements for the maintenance of equipment in buildings. ________________________________________________________________________________ Section 1: General Provisions - this contains information such as definitions, how buildings are to be classified and the list of guidance documents such as Australian Standards that have been referenced by the BCA as Deemed to Satisfy solutions. Section 2: Performance Provisions - this section is further split into five subsections entitled Structure, Damp & Weatherproofing, Fire Safety, Health & Amenity and Safe Movement and Access. Within each subsection the objectives, functional statements and performance requirements are stated. Section 3: Acceptable Construction - this section, also known as the Acceptable Construction Manual, contains the Deemed to Satisfy building solutions for Class 1 and 10 buildings. The section is split into 11 subsections, namely Site Preparation, Footings & Slabs, Masonry, Framing, Roof & Wall Cladding, Glazing, Fire Safety, Health & Amenity, Safe Movement and Access, Additional Construction Requirements and Structural Design Manuals. _________________________________________________________________________________ The following resources, available for download, have been created to assist designers and architects develop timber constructions so that they are consistent with the requirements of the codes stipulated by the BCA building classes:
Visit our Technical Design Guides Page to see the full set of WoodSolutions guides (You need to be logged in to WoodSolutions to download resources from this section) |